This items is made to order and is not returnable and order cannot be canceled.

CUSTOM ITEM: Guard Column Starter Set, Bidentate C8, complete with 5 each 2.0 mm ID x 10 mm long cartridges packed with 5 um, 300 A phase and 1 each guard column holder. Cogent TYPE-C Brand. 1 EA.

Additional Info:

The 40008‑PG1‑3 Cogent Bidentate C8 Guard Column Starter Set provides a complete protection system for analytical HPLC columns, especially when working with large‑pore stationary phases and biomolecule‑compatible methods.

This starter kit includes:

Each cartridge is individually stored in a closeable Delrin™ case, protecting against contamination, drying, and physical damage prior to use.

The included holder is compatible with all Cogent TYPE‑C™ guard cartridges, allowing flexible use across methods.

Designed for 2.1 mm Analytical Columns

This starter kit is optimized for:

  • 2.1 mm ID analytical HPLC columns

  • LC‑MS applications

  • Larger‑molecule or biomolecule separations

Proper guard column matching ensures:

  • Minimal band broadening

  • Maintained chromatographic efficiency

  • Consistent method reproducibility

Why Use a Guard Column Starter Kit

Analytical columns are vulnerable to:

  • Particulates and sample debris

  • Strongly retained contaminants

  • Protein or biomolecule fouling

  • Irreversible phase damage

The 40008‑PG1‑3 starter kit provides a sacrificial protection layer, helping to:

  • Extend analytical column lifetime

  • Maintain consistent performance

  • Reduce maintenance costs

  • Improve reproducibility

Under typical use, the five included cartridges may protect a column for its full working lifetime, depending on sample cleanliness.

300 Å Pore Size Advantage

The 300 Å pore size is specifically suited for:

  • Large molecules and biomolecules

  • Peptides and protein‑related compounds

  • Complex biological matrices

  • Applications requiring improved accessibility to stationary phase surface

Compared to 100 Å phases, 300 Å:

  • Reduces steric exclusion effects

  • Improves recovery of larger analytes

  • Enhances consistency in biological separations

Bidentate C8 Guard Phase Advantages

Using the same phase as your analytical column provides:

  • Matched selectivity and retention behavior

  • No method re‑validation required

  • Consistent analyte transfer to the main column

Compared to C18:

  • Reduces excessive retention

  • Improves recovery of amine‑containing compounds

  • Provides alternative selectivity for complex samples

Cogent TYPE‑C™ Technology Benefits

Silica Hydride Surface

  • Reduced silanol interactions

  • Improved peak shape for basic compounds

  • Lower secondary interactions

Faster Equilibration

  • Reduced method cycle times

  • Increased throughput

Durability

  • Resistant to hydrolysis

  • Long cartridge and column life

  • Stable under demanding analytical conditions

Typical Applications

  • LC‑MS and biomolecule analysis

  • Peptides and protein‑related separations

  • Pharmaceutical and bioanalytical workflows

  • Complex biological matrices

  • Analytical methods requiring column protection

Made‑to‑Order & Pricing Information

This is a custom, made‑to‑order item.

  • Orders cannot be canceled once placed

  • Custom items are non‑returnable

Custom Order Item. Inquire for more information.

© Copyright 2026. MICROSOLV. All Rights Reserved. Website & Hosting by BlueTone Media